Bi-Directional Air Motor Control System
(Diagram 4b)
Click Picture for Larger View
Air Motor
Series |
Main
Valve
Rating |
Main Valves
2 Needed |
Main
Pipe
Size |
Main
Hose
Size |
Silencers For
Main Valves
2 Needed |
Silencer
For
Air Motor |
Lubricator |
Speed
Control
Valves
2 Needed |
|
(Cv) |
(ref #) |
(inch) |
(inch) |
(ref #) |
(ref #) |
(ref #) |
(ref #) |
DV6
DV10 |
24
20 |
C-1 1/2
C-1 1/2 |
1
1 |
1 1/4
1 1/4 |
S-1 1/2
S-1 1/2 |
S-3/4
S-1 1/2 |
T-3/4
T-1 |
A-3/4
A-1 |
DV20
DV42 |
40
40 x 2 |
C-1 1/2
C-1 1/2
4 Needed |
1 1/4
1 1/4 |
1 1/2
1 1/2 |
S-1 1/2
S-1 1/2
4 Needed |
S-2A
S-2A
2 Needed |
T-1 1/4
T-2 |
A-1 1/4
A-2 |